Resources

Data Sheets

2 Door
EZ ModLock 2 Door Datasheet
Download
2 Door Expansion
EZ ModLock 2 Door Expansion Datasheet
Download
2 Door Timer
EZ ModLock 2 Door Timer Datasheet
Download
Multi Door Basic
EZ ModLock Multi Door Basic Datasheet
Download
Multi Door Access
EZ ModLock Multi Door Access Datasheet
Download
Multi Door Timer
EZ ModLock Multi Door Timer Datasheet
Download
Door Interlock Accessories Datasheet
Download

Product Documents

Limited Product Warranty
EZ ModLock Limited Product Warranty
Download
Module Feature Matrix
Module Feature Matrix
Download
Installation Manual
Request Access
Wiring Diagrams
Wiring Diagrams
Request Access
CSI Specifications
CSI Specification
Download

Interlock Logic

L1
L1 Logic (also known as “Room Logic”)
View
L2
L2 Logic (also known as “3+1 Logic”)
View
L3
L3 Logic (also known as “Multiple-step Airlock”)
View

Flyers

Sentry Interlocks Flyer
Download

Product Animations

Sentry Interlocks General Overview
Watch
Manual Doors, Normally Unlocked 1

Using Sentry Cat5 Indicators

Watch
Manual Doors, Normally Unlocked 2

Using Wired Indicators

Watch
Manual Doors, Normally Locked 1

Using Sentry Cat5 Indicators and Sentry REX Devices

Watch
Manual Doors, Normally Locked 2

Using 3rd Party Wired REX Devices and Sentry Cat5 Indicators

Watch
Manual Doors, Normally Locked 3

Using 3rd Party Wired Indicators and REX Devices via Sentry RJ45 Adapter

Watch
Automatic Doors 1

Using Sentry Cat5 Indicators and Sentry REX Devices

Watch
Automatic Doors 2

Using 3rd Party Wired REX Devices and Sentry Cat5 Indicators

Watch
Automatic Doors 3

Using 3rd Party Wired Indicators and REX Devices via Sentry RJ45 Adapter

Watch
Fire Alarm and Emergency Setup
Watch

Installation Manual

Wiring Diagrams

L1 Logic (also known as “Room Logic”)

also known as “Room Logic”

L1 Logic (also known as “Room Logic”) is available for 2 to 10 door mantraps providing a standard interlocking scenario ~ if one door is open, all the other doors are locked.

L2 Logic (also known as “3+1 Logic”)

also known as “L2 Logic”

L2 Logic (also known as “3+1 Logic”) is available for 4 or more door mantraps where different combinations of doors being locked or unlocked are required.

L3 Logic (also known as “Multiple-step Airlock”)

also known as “L3 Logic”

L3 Logic (also known as “Multiple-step Airlock”) is a very frequent logic used to set up multiple step mantraps designed to enter to a production area or classified space from a non-classified area. Used with one room after another which appears to be a tunnel or corridor divided by doors. “L3” Logic is available for applications of 3 to 10 interlocked doors.